all phases of operation, service and repair of this instrument. Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. RS-485 interface allows to connect up to 30 devices with one remote master unit. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. Can I output in the 100% direction (20 mA or more) upon burnout? The instrument have one complete parameter set. Enter your email address and check your inbox. The conguration parameters are collected in various groups. IP65 Certification when the optional panel gasket is mounted. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. If the other instruments have an SG terminal, how should I wire it? The shallow depth of the controller helps to save instrument panel space. all phases of operation, service and repair of this instrument. On the TC10, I want the difference lower limit alarm to be ON 5C below the setpoint value. 6. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. The instrument will turn OFF all LEDs for a few seconds, then the upper display will show dFLt (default) and then all LEDs are turned ON for 2 seconds. Id like to confirm the parameters that can be set for TC10 RS485 communication setting criteria (protocol, baud rate, parity, stop bit, data length). When the instrument is powered, it starts immediately to work according to the parameters values loaded in its memory. Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. These meters commonly measure voltage, resistance, continuity, capacitance, and more. Do not use it, for measurements in locations falling under Measurement Catego-, For measurements performed on circuits not directly, For measurements performed on circuits directly. Is there a controller to which I can connect a 2-wire Pt1000 sensor? The shallow depth of the controller helps save to space. All information about. the protection provided by this instrument may be impaired. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery. What settings should I use to output PV transmission from ananalog output terminal on TC10? There is no parameter for specifying the output direction. Can't find your region? Can't find your region? The instrument will show a measured value up to 5% less than SSc value and then it will show an underrange error. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to . A short press allows to exit from the current parameter group and select a new parameter group. Before connecting the output actuators, we recommend to congure the parameters to, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. The Yokogawa TC10 is a compact, all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. The following general safety precautions must be observed during. Pt 1000 input circuit: Current injection (15,5 A). Can I turn off the "C" display with input other than temperature on TC10? that no power is being supplied to a cable to be connected. the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. The short depth of the controller helps save instrument panel space. 0 mA = 0 mBar and 20 mA = -1000 mBar (vacuum). fail to observe these instructions when operating the product. I'm sending the temperature via PV transmission on TC10. values and the controller output instantaneous value. This manual describes how to use UT55A/UT52A functions other than UT55A/UT52A's communication function and ladder sequence function . I want to use it as a display. Calibration: According to EN 60751/A2. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. Download Instructions manual of digitalview ALR-1400 Controller for Free or View it Online on All-Guides.com. 1.Do not run input wires together with power cables. Copyright 1994-2023 Yokogawa Electric Corporation. Every group denes all parameters related with a specic function (e.g. The short depth of the controller helps save instrument panel space. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. TC10 does not come with a terminal cover. A reinforced isolation must be assured by the external solid state relays. Select a mounting location having the following characteristics: 2. NOTE: This parameter will be shown only when a linear input has been selected (mV, V or mA). Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. TEMPERATURE . There is minimum vibrations and no impact; There are no water or other uids (i.e. The UT32A-D is a compact digital indicating controller with selectable 2-loop control. SKU:WE4537266 Approximately 2 seconds or less. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 48 PV Optional gasket 1.2 PANEL CUT-OUT 45 +0.6 mm 1.78 +0.023 TC10-L is capable of a retransmission output and up to two alarm outputs. parameter and than you can use the instrument. Can I use the DI function to switch between auto/manual and between run stop/start? The shallow depth of the controller helps to save instrument panel space. TC10s compact design allows for a broad range of applications/uses while maintaining a high level of accuracy. IM 05C01E81-11EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10-L is a panel mounting, Class II instrument. What is the measured current of the TC10's RTD input? rear housing, exposed terminals and wiring on the back. and workmanship for 18 months from the date of manufacturing. 3. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. a TC J input is programmed). Controller YOKOGAWA TC 10-L Engineering Manual 20 pages. desired, the optional gasket must be mounted. the protection provided by this instrument may be impaired. . [3] SSc - Initial scale read-out for linear inputs. the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. Can you issue a TC10 calibration certificate? 1. Allows to decrease the value of the selected parameter. Can I hide the SP display? This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. In other words the upper display will show: ]INP. 0/4 to 20 mA input wiring for passive transmitter using the auxiliary pws. The short depth of the controller helps save instrument panel space. equipment and devices that ensure personnel safety. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Compliance: directive EMC 2004/108/CE (EN 61326-1), directive LV 2006/95/CE (EN 61010-1). For measurements performed in the building, For measurements performed at the source of, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. When the maximum front protection (IP65) is. Model: TC10 Digital Indicating Controller with one universal input, one control output, and one selectable I/O. Does the TC10 come with a terminal cover? Moreover, provide indication that the. Available: When a linear input is selected by [1] SenS. I'm sending the temperature via PV transmission on TC10. TC10-L is a panel mounting, Class II instrument. When the upper display is showing a group and the lower display is blank, this key allows to enter in the selected group. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. Notes: 1. : input type, Control strategy, alarms, etc.). Select a mounting location having the following characteristics: 2. All information about. ), Panel cutout: 45[-0, +0.6] x 45[-0, +0.6] mm (1.78[- 0.000, +0.023] x 1.78[- 0.000, +0.023] in.). For complete controller configuration see the Engineering Manual. The shallow depth of the controller helps to save instrument panel space. Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display Universal input: (TC, mV, V, mA, Pt100-Pt1000) 4 Set Points and alarm functions Serial communication : RS-485 Modbus PID control, ON/OFF, Auto-tuning At this point you can set the operator. 5, the lower display is showing its value, this key allows, to store the selected value for the current parameter. The readout is updated every 15 minutes. There are no water or other fluids (i.e. Input circuit: Current injection (135 A). The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Products and components that are subject to wear due to conditions. Third edition: Feb. 2018. . 2.It is possible to set a initial scale read-out higher than the full scale read-out in order to obtain a reverse read-out scaling. connected to the low-voltage installation. be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY, The following general safety precautions must be observed during. Copyright 1994-2023 Yokogawa Corporation of America. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. There are no water or other fluids (i.e. 4 2.4 SERIAL INTERFACE. mA output: 0/4 20 mA, galvanically isolated, RL max. : control, alarms, output functions). - Do not short-circuit the terminals of the SSR output. 1. Please, provide a T type 1A, 250 V fuse externally. use only, in an electrical panel which encloses the rear housing. US $17.58. It also includes a ladder sequence function. The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Brand: digitalview. Category: Controller. terminal 1 and 2 to transmitter signal output. Note: For TC and RTD inputs the decimal figure must be 0 or 1 only. There's no SG terminal for wiring RS485 communication on the TC1. This is a list of recorder and controller products that support the New Legislative Framework (NLF.). The following general safety precautions must be observed during. This instrument is intended for permanent installation, for indoor use only, in an electrical panel which encloses the rear housing, exposed terminals and wiring on the back. YOKOGAWA Accessory Manuals 12 Devices / 14 Documents Full list of YOKOGAWA Accessory Manuals YOKOGAWA AC Power Distribution Manuals 1 Devices / 1 Documents YOKOGAWA Adapter Manuals 9 Devices / 10 Documents ), Panel cutout: 45[-0, +0.6] x 45[-0, +0.6] mm, (1.78[- 0.000, +0.023] x 1.78[- 0.000, +0.023] in.). The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed: Linear 0 to 20 mA (this selection forces Out 4 = TX), Linear 4 to 20 mA (this selection forces Out 4 = TX), Note: As default, when the alarms are active, only AL1 threshold, is available at "Operator Command" level to perform non, critical tasks. Model: TC10 - Quick Guide . 1 to 4 indicate the status of outputs 1 to 4. switch is a device for turning off the power to the instrument. What settings should I use to output PV transmission from ananalog output terminal on TC10? The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the. Note: During the test, the instrument continues to operate at the measurement accuracy within specication. 2.56 in min. 2.Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. The output relay is always de-energized (opened) at poweron,even if PV does not exceed SP(A). Features 3 Dynamic Colors Led Display Compact size: 48 x 48 mm (1/16 DIN), depth 48 mm The shallow depth of the controller helps to save instrument panel space. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. When a shielded cable is used, it should be connected at one point only. TC10. When you do this, the upper limit range of 1000C becomes 999.9C. Yokogawa Electric Corporation for this Product in the EEA. The TC10 supports easy configuration with codes for quick start-up. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. Do I need a minus sign ( - ) on the alarm setting value? Line resistance: Automatic compensation up to 20W/wire with maximum error 0.1% of the input span. At this point the instrument restarts as for a new power ON. (24 VAC/DC), 6.0 VA max. 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm; Dimensions: 48 x 48, depth 73 mm, (1.89 x 1.89 x 2.87 in. The SP value is not displayed if you dont specify a control operation. that no power is being supplied to a cable to be connected. The shallow depth of the controller helps to save instrument panel space. At power ON the instrument can operate in two different mode according to the value assigned to [34] r.md parameter [34] r.md equal to 0, (Limit output is de-energized at power on in any cases.). For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. The output (OUT) display lamp is lit. 2.56 in min. [4]FSc - Full scale read-out for linear input. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional), Power consumption: 4.5 VA max. SSR outputs are not isolated. All information about the controller use can be found in the Engineering Manual: - IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. Case: Plastic, self-extinguishing degree: V-0 according to UL 94; Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1; Terminals protection: IP 20 according to EN 60070-1; Terminal block: 16 screw terminals for cables of. The TC10 supports easy configuration with codes for quick start-up. The SP value is not displayed if you dont specify a control operation. This action allows to put the instrument in a dened condition (the same it was at the rst power ON). Set detailed parameter out group o1.F (output 1 function) = r.inP. 5.5 KEYBOARD FUNCTIONS DURING PARAMETER CHANGING. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. facilities, aviation facilities, and medical equipment. IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. Yokogawa TC10-L Temperature Controller Datasheet PDF, Yokogawa TC10-L Limit Controller Quick Reference Guide, Yokogawa TC10-L Temperature Controller Manual PDF, Yokogawa TC10-L Temperature Controller Brochure PDF, Yokogawa UT150L to TC10-L Cross Reference Guide PDF, Universal Input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), Includes one digital input for external limit reset. 600W. The EU Declaration of Conformity and the manual of the controller. The Yokogawa TC10 is a compact,all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. View and Download Yokogawa TC10-L instruction manual online. Download digitalview ALR-1400 Instructions manual . and workmanship for 18 months from the date of manufacturing. [34] r.md equal to 1(Limit output is de-energized at power on in any cases. use only, in an electrical panel which encloses the rear housing. Pay attention to the line resistance; a high line resistance may cause measurement errors. TC10-L is a panel mounting, Class II instrument. condensation); 5. Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display Only wire the other instruments SG terminal. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. Use a tester or similar device to ensure. A ladder sequence function is included as standard. AL on the front of the TC10 is the alarm lamp. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O, Upload manuals that we do not have and get. The 3-year warranty extends 36 months after shipment from our factory. Related Manuals for YOKOGAWA TC10-L . 1. The factory default password for conguration parameters is equal to 30. Note: For TC wiring use proper compensating cable preferable shielded. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. requirements of the area in which the instrument is being installed. - For control relay output, alarm relay output, and power terminal. If the other instruments have an SG terminal, how should I wire it? External components (like zener barriers, etc.) Set detailed parameter out group o1.F (output 1 function) = r.inP. Do not use it, for measurements in locations falling under Measurement Catego-, For measurements performed on circuits not directly, For measurements performed on circuits directly. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. Supply Voltage: 100 to 240 VAC (-15 to +10%). 16 AWG or larger wires rated for at last 75C. voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. The input resolution specification the TC10 is 30000. What is the measured current of the TC10's RTD input? that no power is being supplied to a cable to be connected. 1 to 4 indicate the status of outputs 1 to 4. Sometime, e.g. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required. condensation); 5. Controller YOKOGAWA TC 10-L Engineering Manual, Controller YOKOGAWA UT350 Instruction Manual, Controller YOKOGAWA FX103 User Manual, Controller YOKOGAWA UT32A User Manual, Controller YOKOGAWA UTAdvanced UT35A Technical Information. If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features Model: digitalview ALR-1400, digitalview 417100041-3. I want to use the detailed parameter setting method of TC10, but what number is the password? IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. Do not run logic input wiring together with power cables; The instrument needs 150 ms to recognize a contact status variation; To avoid electrical shocks, connect power line at last. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. D + D - D + D - D + D - D + D - RS-485 5 6 exposed terminals and wiring on the back. Can I hide the SP display? Notes: 1. period. Yes, by changing the DP setting from 0 to 1. SSR outputs are not isolated. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required, Temperature Controllers 2D CAD *Log-in Required, Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional). 7. and General Specification: GS 05C01E81-11EN. The UT32A/MDL supports 920 MHz band wireless communication. - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. equipment and devices that ensure personnel safety. Fsc allows the scaling of the analog input to set the maximum displayed/measured value. 16 AWG or larger wires rated for at last 75C. Input impedance: > 1 MW for mV Input 500 kW for Volt Input. (63% response when the input changes from 10% 90%). The UT75A also support open networks such as Ethernet communication. Can I use the DI function to switch between auto/manual and between run stop/start? When using an external power supply with 2-wire wiring of TC10, what is the input resistance when inputting 4-20 mA? To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. Brand: YOKOGAWA . The 3-year warranty extends 36 months after shipment from our factory. The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. If so used, it is the user's responsibility to include in the system additional. For supply connections use No. The UT52A/MDL supports 920 MHz band wireless communication. connected, between sensor and input terminals may cause errors in, measurement due to excessive and/or not balanced line, 3. can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. Select a mounting location having the following characteristics: 2.There is minimum vibrations and no impact; 4.There are no water or other uids (i.e. Clamp meters can perform analyses in the field on live conductors without interrupting the circuit. observe these instructions when operating the product. Yokogawa TC10-L Manual Download for 1 TCTC10- L LIMIT CONTROL TYPE Engineering Manual Code: IM 05C01E81-12EN First edition: Nov. 2019 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. connected to the low-voltage installation. When installing the TC10, what is the depth in millimeters from the surface of the panel? On the TC10, what does it mean if AL and 1 are lit? Range: When the code of the input type is equal to c (see paragraph How to order).
Quincy, Ma Police Department Arrests,
Rangeview High School Website,
Articles Y